  1. #Eplan template software#
  2. #Eplan template professional#

  • Manage grid settings – inch vs mm setting (very important).
  • Manage plot frame inside your EPLAN project.
  • Add pages and compare the differences between an IEC and an NFPA style ePLAN project.
  • Create an EPLAN project using a correct NFPA project template (not intuitive).
  • All you need to know to be able to work in EPLAN acc.
  • We will finish up the course by creating a direct-on-line (DOL) motor starter power circuit diagram.

    eplan template

    #Eplan template professional#

    When there is a problem with the symbol library, the solution is to copy the symbol libraries such as IEC_symbol.slk and IEC_symbol.sdb in the "symbol / companycode" folder under the EPLAN installation path to "project / companycode / project name.sdb" and overwrite Just have the existing file.By the end of the course, you will be able to add pages and manage plot frames and grid sizes to create professional NFPA style ePLAN circuit diagrams. In addition, it is generally not recommended to directly modify the symbol library that comes with the system, such as IEC or GB library, but to create a new symbol library and copy the similar symbols in the standard library to your own symbol library for modification. When editing the EPLAN symbol, after completing the symbol, pay attention to using the "check symbol" tool to ensure that the symbol is correct, and then close the symbol library. The reason is that there is an error in the previously edited symbol library. The symbol just edited still changes the previous content. After editing the symbol library, it prompts that it cannot be synchronized due to compatibility reasons. ⑤ The color of the lines in the graphic may use "reverse to background"Ĥ. ④The output folder contains Chinese or full-width characters (for example, it cannot be output to the user's desktop, because the desktop folder under the Chinese system is "C: \ Documents and Settings \ Administrator.CAODAPING \ Desktop", and the English operating system is "C : \ Documents and Settings \ Administrator.CAODAPING \ Desktop ", so it can output normally

    #Eplan template software#

    ③ The layer contains Chinese or full-width characters (mostly because free graphics drawn in other CAD software are imported from outside, and the graphic contains Chinese layers) ②The project name contains Chinese or full-width characters ① File name contains Chinese or full-width characters An error occurred when exporting DWG / DXF drawings, prompting that it cannot be exported (only 1.8 and previous versions, there is no such problem in later versions) PS: The contacts of the relay are generally switching contacts, with 3 connection points do not mix with the auxiliary contacts (2 connection points) of the contactor, otherwise there will be problems with the selection.ģ. The solution is to switch to "Function Templates" in the Parts Manager and add the complete function templates. If there is no function definition, EPLAN cannot call the symbol, which will happen. When a device is inserted, EPLAN will query the corresponding default symbol in the symbol library according to the existing function definition. This is because the part definition is not complete. Insert a custom device into the schematic, the system prompts "Display: The selected component must contain the following information :, 1) Macro 2) Function template 3) Symbol file and symbol number" Remember not to choose "beginner" anymore.Ģ. If you need to redisplay the prompt dialog, enter the software and select the menu " Options → Settings → Users → Display → User Interface ”, select“ reactive suppressed messages ”, the next time EPLAN starts, the user selection dialog will pop up again. If you select "Beginner" for the first time and check "Don't show this dialog again", the system will not prompt the user when starting up in the future. The purpose is to allow beginners to focus on the design of the schematic.

    eplan template

    The system only displays commonly used menu items. There are also menu items such as "Export → DWG" and "Export → PDF" under the page menu. After selecting "beginner", it will be This problem occurs. The content displayed in the menu and user permissions are different. When EPLAN starts, the user will be prompted to select three types of users: "beginner", "advanced" and "expert". "According to the current regulations in rights management, it is not allowed to enter texts that are not in the dictionary"? Why do you get a prompt when entering text in the functional text area (or free text area, remarks area), etc.